Parameter
Read Back
Accuracy
Voltage ripple
*1
Setup Temperature
Coefficient
Read Back Temper-
ature Coefficient
Rise Time( no load )
Rise Time( full load )
Fall Time( no load )
Fall Time( full load )
Transient Response
Time
(change from 25%
to 90% of rated
current)
Line Regulation
Load Regulation
Output protection
Remote Sense
Compensation
Voltage
External analog
(optional)
Voltage
Current
Power
Vp-p
Vrms
Voltage
Current
Voltage
Current
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Current
Voltage
Current
OCP
OVP
Overpower
protection
current program
current monitor
voltage program
Voltage 0 to 800V corresponds to external monitor-
voltage monitor
Copyright © Itech Electronic Co., Ltd.
IT-M3906D-800-24
≤0.03% + 0.03%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1000mVpp
≤160mV
≤30ppm/℃
≤50ppm/℃
≤30ppm/℃
≤50ppm/℃
≤30ms
≤60ms
≤100ms
≤0.01% + 0.01%FS
≤0.03% + 0.03%FS
≤0.01% + 0.01%FS
≤0.05% + 0.05%FS
≤8V
External programming voltage 0V to 10V corre-
sponds to current 0A to 24A
Current 0A to 24A corresponds to external moni-
toring voltage 0V to 10V
External programming voltage 0 to 800V Corre-
sponding voltage 0 to 10V
ing voltage 0 to 10V
Technical Specification
≤1s
≤1ms
25A
808V
6120W
166