Parameter
Read Back Temper-
ature Coefficient
Rise Time( no load )
Rise Time( full load
)
Fall Time( no load )
Fall Time( full load )
Dynamic response
time
(change from 20%
to 90% of rated
current)
Line Regulation
Load Regulation
Output protection
Remote Sense
Compensation
Voltage
External analog
(optional)
Other parameters:
AC Input
*2
Current
Voltage
Current
Voltage
Voltage
Voltage
Voltage
Voltage
Voltage
Current
Voltage
Current
OCP
OVP
Overpower
protection
current program
current monitor
voltage program
voltage monitor
Grid voltage range
Frequency
Copyright © Itech Electronic Co., Ltd.
IT-M3906D-300-60
≤50ppm/℃
≤30ppm/℃
≤50ppm/℃
≤0.01% + 0.01%FS
≤0.03% + 0.03%FS
≤0.01% + 0.01%FS
≤0.05% + 0.05%FS
≤3V
External programming voltage 0V to 10V corre-
sponds to current 0A to 60A
Current 0A to 60A corresponds to external moni-
toring voltage 0V to 10V
External programming voltage 0 to 300V Corre-
sponding voltage 0 to 10V
Voltage 0 to 300V corresponds to external monitor-
ing voltage 0 to 10V
3phase 200V~480V
Single phase 100V~240V
Technical Specification
≤30ms
≤60ms
≤1s
≤100ms
≤1ms
63A
303V
6120W
50/60Hz
146