Terex TL120 Operating Instructions Manual page 76

Wheel loader
Table of Contents

Advertisement

7
Care and Maintenance
7.8.4
Fuel system
7.8.4.1
Checking the fuel level
Check the fuel level using the fuel gauge (39/27).
Danger of injury
due to excessive pressure while refueling.
• Open the fuel tank cap when topping up
fuel using the electric refueling pump to
avoid excessive pressure in the fuel tank!
Top up fuel every day after use to prevent
condensation from forming before the machine is
next put into operation.
7.8.4.2
Draining the water separator
Machine damage
due to full water separator.
Never allow the engine to run if the water
separator is filled by more than 50%. Failure
to do so will result in damage to the engine.
Check daily using the sight glass (40/1) and drain
if required.
Open the drain (40/2) and collect any escaping
water in a suitable container.
Dispose of the water according to regulations.
Close again the drain (40/2).
76
Fig. 39 Checking the fuel level
1
2
Fig. 40 Draining the water separator
Operating Instructions Wheel Loader TL120
27
L824-038

Hide quick links:

Advertisement

Table of Contents
loading