7.8.14 Injection valves
Injection valves must be checked by your service
specialist.
7.8.15 Electrical equipment
7.8.15.1 Battery
The battery is located under the right-hand side flap.
Attention
Instructions from the battery manufacturer
must be observed when using the battery for
the first time.
Only check the battery with the engine not running.
The acid level should be approximately 10 mm
above the edges of the plates. Top up with pure
distilled water where necessary.
Attention
This check is not necessary for maintenance-
free batteries.