Lenovo Converged HX Series Installation And Service Manual page 213

Table of Contents

Advertisement

076F0AC7
Full Sensor Name (Sensor Name In SDR):
PROC_Hot
Sensor Type:
Processor
Event Severity:
Warning
Description:
Processor Automatically Throttled - Asserted
Message:
CPU begins to throttle which is triggered by PSU alert.
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error remains, contact Lenovo service representative for execution of processor replacement.
• Diagnostic Code:
CF6F00C9
Full Sensor Name (Sensor Name In SDR):
Chassis_Control
Sensor Type:
Customer Sensor Type
Event Severity:
Info
Description:
Chassis Control - Asserted
Message:
BMC gets Chassis Control command.
Actions:
Information only. There is no need to do anything for this message.
• Diagnostic Code:
070301D0
Full Sensor Name (Sensor Name In SDR):
CPU_CATERR
Sensor Type:
Processor
Event Severity:
Critical
Description:
State Asserted - Asserted
Message:
Appendix A. TMM error messages
199

Advertisement