Lenovo Converged HX Series Installation And Service Manual page 190

Table of Contents

Advertisement

Sensor Type:
Temperature
Event Severity:
Critical
Description:
Upper Critical - Going High - Asserted
Message:
DIMM Group% temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, reseat the DIMMs and monitor the status.
4. If the error recurs, replace the DIMMs.
• Diagnostic Code:
0101072A
0101072B
Full Sensor Name (Sensor Name In SDR):
DIMMG%_Temp (% = Group number)
Sensor Type:
Temperature
Event Severity:
Warning
Description:
Upper Non-Critical - Going High - Asserted
Message:
DIMM Group% temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, reseat the DIMMs and monitor the status.
4. If the error recurs, replace the DIMMs.
• Diagnostic Code:
01010B2C
01010B2D
01010B2E
01010B2F
Full Sensor Name (Sensor Name In SDR):
DIMM%_VR_Temp (% = Channel number)
Sensor Type:
176
Lenovo Converged HX3710, HX2710-E, HX3710-F Type 8689, Lenovo Converged HX Enclosure Type 5495 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents