Lenovo Converged HX Series Installation And Service Manual page 203

Table of Contents

Advertisement

PSU_Mismatch
Sensor Type:
Power Supply
Event Severity:
Critical
Description:
Configuration Error - Asserted
Message:
There are different capacity or voltage of PSUs that are plugged in chassis.
Actions:
1. Make sure the same type of power supply units are installed.
2. Restart the server.
• Diagnostic Code:
086F00A1
086F00A2
Full Sensor Name (Sensor Name In SDR):
PSU%_Status (% = PSU number)
Sensor Type:
Power Supply
Event Severity:
Critical
Description:
Presence detected - Deasserted
Message:
PSU is unplugged
Actions:
1. Remove and install the power supply unit, and make sure it is properly connected to the power.
2. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
086F01A1
086F01A2
Full Sensor Name (Sensor Name In SDR):
PSU%_Status (% = PSU number)
Sensor Type:
Power Supply
Event Severity:
Critical
Description:
Power Supply Failure detected - Asserted
Message:
PSU is OCP or OVP
Appendix A. TMM error messages