Windhager PUROWIN PWPE 60 Installation Instructions Manual page 34

Pellet boiler
Hide thumbs Also See for PUROWIN PWPE 60:
Table of Contents

Advertisement

For the installer
13.5.6
Installing the cladding door and operating panel
f Hook the cladding door on at the bottom (Fig. 82), disconnect the operating panel; remember to hook the cladding
doors onto the bolts first – Fig. 84.
f Secure the operating panel on the left and right using 2 Torx screw on each side – Fig. 85.
Fig. 83
Cladding door and operating panel
Fig. 85
Internally securing the operating panel on the le and right
f Adjust the cladding; adjust the side walls, cladding door and control panel by eye based on the width of the cladding
door or make the gap size equal and then tighten all screws, including the 2 hexagon bolts for the top connector (see
Section 13.5.2 on page 24).
f Adjust the door safety switch so that, when the cladding door is closed, there is still sufficient shifting travel left
after switching (audible clicking) up until the point at which the cladding door is totally closed. If necessary, to
readjust the switch – Fig. 86, Fig. 87.
Fig. 86
Adjusting the door safety switch PuroWIN PWPE 60
Fig. 82
Fig. 84
2 of each
Fig. 87
34
Hooking on the cladding door at the bottom
Attaching the operating panel, hooking cladding door onto bolts
Adjusting the door safety switch PuroWIN PWPE 75–100

Advertisement

Table of Contents
loading

This manual is also suitable for:

Purowin pwpe 75Purowin pwpe 90Purowin pwpe 100

Table of Contents