For the installer
f Take 1–2 M5x12 self-threading TT screw (this will be used for hooking on the cladding) and screw it halfway into the
base on the bottom left-hand side at the back – Fig. 28.
f Hook the left side panel onto the screw on the bottom left, making sure that the cladding is behind the connection
panel, the level control proximity switch [1] and the flange – Fig. 29.
Fig. 28
Screwing in the screw halfway
Note!
Before installing the side panel, you must remove the rear panel that has been stuck inside the side panel –
Fig. 25.
Fig. 29
Installing the le side panel (Illustration PuroWIN PWPE 60)
1 ....... Level control proximity switch (LC 12V)
2 ....... Ember bed slide proximity switch (GB 12V)
3 ....... Ash scraper proximity switch (AS 12V)
4 ....... Ember bed slide motor (GB 230V)
5 ....... Ash scraper motor (AS 230V)
1 x
TT M5x12
1
4
5
21
2
2
3
3