PREPARATIONS

2-1

ORDERING DETECTOR BATTERIES

Specified batteries: Four LSH20 batteries manufactured by SAFT
For information about batteries, visit the following website and contact your local SAFT sales representative.
http://www.saftbatteries.com/battery-search/ls-lsh/
2-2

CHECKING THE WIRELESS TRANSMITTER SIZE

Use two wireless transmitters for the each of receivers and transmitters. When wireless transmitters with two or
more inputs are available, use one wireless transmitter for the each of transmitters and receivers.
The following figure shows the dimensions of the wireless transmitter installation space in the back box. Note that
transmitters with dimensions greater than those are not applicable.
42.5 (1.67)
26.5
(1.04)
3

INSTALLATION

3-1

WALL MOUNTING

Remove the chassis from the back box.
1
42.5 (1.67)
66 (2.60)
26.5 (1.04)
Unit: mm (inch)
Fix the chassis to the wall.
2
Wall mounting screws
(M4×20, supplied)
After mounting the chassis, wiggle the tamper
bushing with your thumb and forefinger to ensure
the tamper works properly.
- 4 -
Note>>
• Be sure to monitor the alarm and low
battery outputs.
• To monitor the tamper output, include
a wireless transmitter supporting three
or more inputs into the system.
Caution