Optex AX-100TFR Series Frequently Asked Questions Manual
Optex AX-100TFR Series Frequently Asked Questions Manual

Optex AX-100TFR Series Frequently Asked Questions Manual

Battery operated photoelectric detectors

Advertisement

F
requently
AX-100TFR
A
sked
AX-200TFR
Q
uestions
For
Battery Operated
Photoelectric Detectors
Reference For Sales Purpose Only
All rights reserved by OPTEX Co., Ltd. 2009

Advertisement

Table of Contents
loading

Summary of Contents for Optex AX-100TFR Series

  • Page 1 AX-100TFR sked AX-200TFR uestions Battery Operated Photoelectric Detectors Reference For Sales Purpose Only All rights reserved by OPTEX Co., Ltd. 2009...
  • Page 2: Table Of Contents

    What is an “intermittent output function”? P. 13 Q-24: What is the “battery saving timer”? P. 14 Q-25: Do lightning damage AX-TFRs? P. 14 Q-26: Q-27: How durable is AX-TFR against vandalism? P. 14 Disclaimer notes P. 15 All rights reserved by OPTEX Co., Ltd.
  • Page 3: Wired Model

    Wired Model Q-02: How did you achieve low energy consumption? A-02: Not only implementing OPTEX low energy design, but also, AX- 100/200TFR adopted high quality aspherical lenses to improve accuracy of beam focus, hence photobeams are more sharply defined and minimized usage of excessive power.
  • Page 4: Q-03: Is Ax-Tfr Compromised In Performance Because It"S Low-Energy Consuming

    Temperature Range: -60 ~ 85 degree C High Heat Durability: 120 degree C Battery Life: 10 years LSH20 CR123A (3.0VDC、1.6Ah) (3.6VDC、13.0Ah) [For more information about the SAFT battery, please refer to a website: http://www.saftbatteries.com/] All rights reserved by OPTEX Co., Ltd.
  • Page 5: Q-06: What Happens If I Use Batteries Other Than Saft"S Lsh20 (3.6V)

    A-11: Low Battery Indicator and Output will be turned on at 3.0VDC. Important note: > Please remove all batteries prior to replacing with new ones. If this is not done, the low battery indication LED will not reset and continues to flicker. All rights reserved by OPTEX Co., Ltd.
  • Page 6: Q-12: How Can I Be Aware Of Low Battery Status

    Wireless transmitter Wireless transmitter with two or more inputs with one input [Instruction manual P.11: OPERATION CHECK describes LED status in details.] All rights reserved by OPTEX Co., Ltd.
  • Page 7: Q-13: Why Can"T I Share Tfr"S Batteries With Wireless Transmitters

    AX-TFRs receives any beam from another wired photoelectric detectors, it becomes a factor of false alarm. In case, using AX-TFRs with OPTEX’s wired photoelectric detectors in the same site, please make sure that any beam does not come in sight of AX- TFRs.
  • Page 8: Q-15: How Long Can Ax-Tfrs Constitute A Linear Protection

    10X the distance of 100/200 feet [30m/60m] from beam transmitters (1000 feet [300m] for AX-100TFR, 2000 feet [600m] for AX-200TFR) [For more detailed information, please refer to the instruction manual P.8: SETTING] All rights reserved by OPTEX Co., Ltd.
  • Page 9: Q-17: Can I Mount Ax-Tfrs On Walls, Poles Or In Towers

    > When inserting the tamper bushing, reception indicators for beam alignment will be disabled. Please complete the alignment tuning before inserting the tamper bushing. [For installation instruction, please refer to P.3-7 of the instruction manual. P.12: SPECIFICATION describes more about the MP-4.] All rights reserved by OPTEX Co., Ltd.
  • Page 10: Q-18: What Features Do Back Boxes Have

    (2) Pre-wired color cables for easier installation. Wiring to wireless transmitters is made as easy as possible. Matching patterns are indicated on a label placed on a side of the box. P.10 All rights reserved by OPTEX Co., Ltd.
  • Page 11: Q-19: What Is An "Ip Rate

    Dust-protected. Ingress of dust is not totally prevented but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or impair safety. Protected against water jets from any direction P.11 All rights reserved by OPTEX Co., Ltd.
  • Page 12: Q-20: Can I Use The "Hu-2" (An Optional Heating Unit) For Ax-Tfrs

    A-23: D.Q. output will send a trouble signal when the beam strength reaches below acceptable levels for more than 20 seconds, due to rain, snow, or heavy fog. D.Q. output will return to “OFF” if reception is regained for more than two seconds. P.12 All rights reserved by OPTEX Co., Ltd.
  • Page 13: Q-24: What Is An "Intermittent Output Function

    > When using this feature, alarm, tamper, low battery and D.Q. outputs are set for intermittent function simultaneously. >Apply same switch settings to the both TX and RX of AX-TFRs to enable the function. P.13 All rights reserved by OPTEX Co., Ltd.
  • Page 14: Q-25: What Is The "Battery Saving Timer

    AX-TFRs. Q-27: How durable is AX-TFR against vandalism? A-27: AX-TFRs are very durable. OPTEX photobeams detectors are equipped with high-grade polycarbonate shells to withstand an attack of hummer. AX- TFRs also features triple tamper detection mechanism that monitors not only the wall attachment, but also front cover removals.
  • Page 15: Disclaimer Notes

    TFRs‟ packages for detailed procedures and setting configurations. The manual as well as catalog, product images and DXF files also can be downloaded from OPTEX website (http://www.optex.co.jp/e/). < End of the Document > P.15 All rights reserved by OPTEX Co., Ltd.

This manual is also suitable for:

Ax-200tfr series

Table of Contents