Summary of Contents for Optex AX-100

  • Page 1 AXTFR Basic configuration guide AX100/200TFRTI Configuration guide...
  • Page 2 AX100/200TFR (30M/60M Battery powered active beams) AX100/200TFR set a new benchmark for reliable, flexible, low maintenance external detection systems. CCTV, Intruder, hazard alerts and numerous other applications can be serviced by this flexible battery powered technology Minimal Compatible system with most...
  • Page 3 AX100/200TFR (30M/60M Battery powered active beams) Undulating ground can cause missed alarms when using long range beams on perimeters Undulating ground can be easily managed with Battery powered AXTFR option and prevent missed alarms...
  • Page 4 In CCTV applications a single long range beam makes it difficult to direct the camera to where the intruder is? Multiple short range beam can direct PTZ to target position...
  • Page 5 AX TFR can provide target recognition in areas where activity is expected but needs to be ignored A ONLY Activated = CLOSED CIRCUIT = No Alarm (Not interesting) B ONLY Activated = OPEN CIRCUIT = ALARM (Possible threat) A+B Both Activated = CLOSED CIRCUIT = Truck (Not interesting) A = NO B = NC These configurations could be reversed to detect larger targets...
  • Page 6 AX100/200TFR (30M/60M Battery powered active beams) AX100/200 TFR can signal an alarm via wireless, GSM, pager or hardwired connection if available. A typical example of cable use is where existing cables are limited or have been damaged. Battery power means that site security can be expanded easily, moved or used as temporary security installations.
  • Page 7 4 Channel frequency makes Tower configuration easy...
  • Page 8 Simple battery replacement Step Step Loosen Remove Step Step Put back Battery replacement does not involve interference with alignment system...
  • Page 9 AX100/200TFR (30M/60M Battery powered active beams) (3)Wall (1)Front Cover (2)Back Box Triple tamper...
  • Page 10 AX TFR can provide security where zone block causes a major problem Conventional solution has higher risk of detection blocking and false alarms AXTFR can overcome and eliminate these problems...
  • Page 11 Early warning for low bridge Secure windows and balcony access Driveways and gates for vehicle and pedestrian detection Monitor access to roof or fire escape No mains power supply needed Simply mount and align the beams...
  • Page 12 AX100/200TFR (30M/60M Battery powered active beams) AX100/200 TFR are supplied as standard with no batteries and no wireless transmitters. This is because the AXTFR can utilize numerous wireless technologies including : Honeywell, Visonic, Scantronics, Inovonics etc Each set of AX100/200TFR require 4 LHS20 batteries to power the devices.
  • Page 13 Common option for CCTV or Intruder Using AX100/200TFRTI Version. (These can also be used with 16 channel 1216M Receiver) Here we have 2 sets of beams signalling Alarm, tamper, low battery and supervisory. The EE1210 is fitted at the AXTFR Transmitter and Receiver...
  • Page 14 Typical option for CCTV Here we have 4 sets of beams signalling Alarm, tamper, low battery and supervisory. The EE1212 is an option to the EE1210. Dome Pre-set Dome Pre-set Note AX100/200TFRTI are supplied fitted with x2 EE1210 and require x4 LHS20...
  • Page 15 Basic option for CCTV or Intruder Here we have 4 sets of beams signalling limited Alarm, tamper, low battery and supervisory. The EE1210 is fitted only at the AXTFR Receiver Note No tamper Signal sent From AXTFR Transmitter...
  • Page 16 AX-100/200TRF Supplied as standard with no batteries and no wireless transmitters. AX-100/200TRFTI Supplied as standard with no batteries and two EE1210 wireless transmitters. LHS20 Batteries Not supplied as standard with any product. Four required for each set of beams Note for Inovonics recievers 4 Channel receiver has 4 Alarm outputs 16 channel receiver has 9 outputs Specifications may change without notice.

This manual is also suitable for:

200tfrAx-100tfrAx-200tfrAx-200tfrti