Specifications - Optex AX-100TFR Installation Instructions Manual

Battery operated photoelectric detector
Table of Contents

Advertisement

8

SPECIFICATIONS

Model
Range
Maximum arrival distance
Detection method
Beam frequency selection
Interruption period
Power Source
Current draw
Transmitter
* Battery life
Receiver
Alarm output
Alarm period
D.Q. output
Low battery output
Output
Tamper output for
**
Front cover
Tamper output
for Back box
Alarm Indicator (Receiver)
Indicator
Power (Transmitter)
Low battery
Operating temperature
Operating ambient humidity
Alignment angle
Mounting
Weight
International protection
Specifications and design are subject to change without prior notice.
* The value is based on the condition that it is used within the ambient temperature range of 20 to 25°C.
** The transmitter is also equipped with AX100/200 TFR (BE).
AX-100TFR
30 m (100 ft.)
265 m (870 ft.)
Infrared beam interruption detection
4 channels
Variable between 50, 100, 250, 500 msec
3.6 V 13.0 Ah: LSH20 lithium batteries
manufactured by SAFT (not included)
Transmitter: 2 units
620 µA
T: 300 µA + R: 320 µA
(at 25°C, 3.6 VDC)
5 years
Form C-Solid State Switch: 3.6 VDC, 0.01 A
2 sec (±1) nominal
Form A/B-Solid State Switch: 3.6 VDC, 0.01 A
Form A/B-Solid State Switch: 3.6 VDC, 0.01 A
(Transmitter & Receiver)
Form C: 3.6 VDC, 0.01 A
activates when cover removed. (Receiver only)
Form C: 3.6 VDC, 0.01 A
activates when either back box or chassis is removed
from the installment.
(1) Light on - IR Beam not received.
(2) Flickering Light - IR Beams not received sufficiently.
(3) Light off - IR Beams received.
Power ON: ON,
Power OFF: OFF
Voltage Reduction: flicker
-20°C – +60°C (-4°F – +140°F)
95% (Max.)
±90° Horizontal, ±5° Vertical
Indoor/Outdoor, Wall/Pole/Tower mounting
(Optional main unit mounting brackets are required,
when the units mount in the tower.)
1600 g (56.5 oz.)
(Total weight of transmitter + receiver, excluding accessories)
- 16 -
AX-200TFR
60 m (200 ft.)
530 m (1740 ft.)
(4 steps)
Receiver: 2 units
810 µA
T: 490 µA + R: 320 µA
(at 25°C, 3.6 VDC)
3 years
5 years
IP55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax-200 tfr

Table of Contents