INSTALLATION INSTRUCTIONS
Laser Scan Detector
Laser Scan Detector
RLS-3060
RLS-3060
FEATURES
* 30 m (Approx. 00 ft.) radius for 90 degrees
* Vertical and horizontal mounting
* Unique detection algorithm
* Four independently adjustable detection areas for PTZ camera
control
* Four independent N.O. outputs
* Form C master alarm outputs
* Automatic area setting function
* Environmental disqualification (EDQ) circuit
* Trouble output
* Tamper output
REDSCAN is an area sensor that configures a fan-like detection
area of 30 m (Approx.00 ft.) radius over 90 degrees arc. using
laser beams.
REDSCAN detects target objects by emitting laser beams at the
target and measuring the time required for the emitted beams to
be reflected and returned to the detector.
There are 3 modes for detecting an intruder. Horizontal Detection
Area, Horizontal Detection Area2 and Vertical Detection Area.
Each one is configured with an independent detection algorithm.
CONTENTS
1 INTRODUCTION
- BEFORE OPERATION ............................................................. 
-2 PRECAUTIONS ........................................................................ 2
-3 PARTS IDENTIFICATION ......................................................... 2
2- TYPES OF INSTALLATION METHOD ..................................... 2
2-2 TYPES OF DETECTION METHOD .......................................... 3
2-3 AREA SETTING PROCEDURE ................................................ 3
ADJUSTMENT .......................................................................... 5
3-3 INSTALLING TO POLE ............................................................. 6
PLANE ...................................................................................... 6
3-5 INSTALLING AT AN ANGLE TO POLE ..................................... 7
4- WIRING ..................................................................................... 7
4-2 RESET SWITCH ....................................................................... 7
4-3 SIGNAL OUTPUT ..................................................................... 7
4-4 CONNECTING WALK TESTER ................................................ 8
4-5 POWERING ON ........................................................................ 8
4-6 SWITCH LAYOUT ..................................................................... 8
4-7 LED FUNCTIONS ..................................................................... 8
5- SELECTOR SWITCH OPERATION ......................................... 8
AREA ........................................................................................ 9
MODE ....................................................................................... 9
6- SELECTOR SWITCH OPERATION ....................................... 0
DETECTION AREA ................................................................. 0
7- WALK TEST .............................................................................
PROTECTION .........................................................................
8- SPECIFICATIONS OF THE MAIN UNIT ................................. 2
8-2 DIMENSIONAL DRAWING ..................................................... 2
8-3 OPTIONS ................................................................................ 2

No.59555-0 2009.3
INTRODUCTION
- BEFORE OPERATION
Read this instruction manual carefully prior to installation.
This manual uses the following warning indications to provide
information regarding correct usage of the product to prevent
you and other people from being harmed, and your assets
from being damaged. These warning indications are described
below.
Ensure you understand these precautions before reading the
rest of this manual.
Do not use the product for purposes other than the
detection of moving objects such as people and
vehicles.
Do not use the product to activate a shutter, etc.,
which may cause an accident.
Do not touch the unit base or power terminals of
the product with a wet hand (do not touch when the
product is wet with rain, etc.). It may cause electric
shock.
Never attempt to disassemble or repair the product. It
may cause fire or damage to the devices.
Do not exceed the voltage or current rating specified
for any of the terminals, doing so may cause fire or
damage to the devices.
Ensure the power is turned off before connecting
wiring.
Confirm the signal name of every terminal to ensure
wiring is carried out correctly.
Whenever a commercial switching regulator is used,
be sure to connect PE (Protective Earth Terminal).
Hold the main unit securely when you install or
service it. Exercise care not to bump the product
against nearby objects or drop it inadvertently.
This product is not capable of detecting objects in the
dead zone of the laser scan.
Do not use this product for an application where it is
not capable of covering the detection area required
by the task.
Please note that the product can malfunction,
including producing an irregular output and
committing a detection error, if it is exposed to
unfavorable environmental conditions such as
strong ambient light, electronic noises or mechanical
vibrations.
Use of controls or adjustments or performance of
procedures other than those specified herein may
result in hazardous radiation exposure.
Clean and check the product periodically for safe use.
If any problem is found, do not attempt to use the
product as it is.
When disposing of this product, be sure to follow the
waste-disposal regulations of the country or region
where it is used.
This product is intended to detect an intruder(s)
and is not designed to prevent theft, disasters or
accidents. The manufacturer shall not be held liable
for any damage to user's property resulting from
theft, disasters or accidents.
-  -
Failure to follow the instructions provided by
Warning
this warning and improper handling may cause
death or serious injury.
Failure to follow the instructions provided by
Caution
this caution and improper handling may cause
injury and/or property damage.
This symbol indicates prohibition.
The specific prohibited action is provided in and/or around
the figure.
This symbol requires an action or gives an instruction.
Warning
Caution

Advertisement

Table of Contents
loading

Summary of Contents for Optex RLS-3060

  • Page 1: Table Of Contents

    • This manual uses the following warning indications to provide information regarding correct usage of the product to prevent you and other people from being harmed, and your assets RLS-3060 RLS-3060 from being damaged. These warning indications are described below.
  • Page 2: Precautions

    -2 PRECAUTIONS -3 PARTS IDENTIFICATION Install the product only on a In the Horizontal Detection solid surface. Area, this product must Mounting bracket Main unit normally be used within the recommended installation height in order to detect an intruder. Cover Cover mounting screw Installation height: 0.7 m to  m...
  • Page 3: Types Of Detection Method

    -Vertical Detection Area when the product is installed at an angle 2-2 TYPES OF DETECTION METHOD The detection method comprises the three modes of Horizontal When you have installed this product at an angle with the optional Detection Area , Horizontal Detection Area 2 and Vertical adjustable angle mounting bracket, the detection area varies as Detection Area.
  • Page 4: Installation And Angle Adjustment

    Auto Remove the mounting bracket from the main unit. P Auto Learning Loosen 4 lock screws. Move the The area automatically learnt by the sensor within the boundary mounting defined by the rough alignment rotary switches and fine bracket adjustment potentiometers. P2 Auto Tracing The area automatically learnt by tracing a person walking a boundary within the area set by the rough alignment rotary...
  • Page 5: Installing To Ceiling Plane And Angle Adjustment

    INSTALLING TO CEILING PLANE Install the cable gland. AND ANGLE ADJUSTMENT When you have selected the Vertical Detection Area for detection purposes, install the product to the ceiling plane. Ensure that any unused Implement steps in “3-” to remove the cover and wiring holes are covered securely with a wiring mounting bracket.
  • Page 6: Installing To Pole

    3-3 INSTALLING TO POLE INSTALLING AT AN ANGLE TO WALL OR CEILING PLANE When installing the product to a pole, use the optional pole mounting bracket (RLS-PB). When installing the product at an angle to a wall or ceiling plane, use the optional adjustable angle mounting bracket (RLS-SB).
  • Page 7: Installing At An Angle To Pole

    Power wires should not exceed the following lengths. 3-5 INSTALLING AT AN ANGLE TO POLE WIRE 24V DC 24V AC When installing the product at an angle to a pole, use the optional SIZE adjustable angle mounting bracket for pole (RLS-SB). 9 mm AWG20 (0.52 mm...
  • Page 8: Connecting Walk Tester

    4-4 CONNECTING WALK TESTER 4-7 LED FUNCTIONS Area A2 alarm output Area A alarm output Area B alarm output Area B2 alarm output Status Power -In the normal operation Symbol Color DETECTOR STATUS Use at “REDWALL” Power selector Area A2 alarm output position.
  • Page 9: Manual Setting Of Horizontal Detection Area

    -Selecting the detection sensitivity -Offset adjustment You can reduce a set detection area using the offset H Manual H Auto H2 Manual H2 Auto V Auto potentiometer. Use this adjusting function when windblown grass Set the detection sensitivity using the Size selector switch and or tree branches interfere with the currently set detection area.
  • Page 10: Setting Vertical Detection Area

    -Setting P2 (Auto Tracing) -Selection of the area setting method H Manual H Auto H2 Manual H2 Auto V Auto H Manual H Auto H2 Manual H2 Auto V Auto Select the desired method using the mode Auto P (Auto Learning) selector switch.
  • Page 11: Auto Setting Of Vertical Detection Area

    -Fine alignment potentiometer AREA CHECKUPS This potentiometer can fine tune the value set with the rough alignment rotary switch by +/-  m. within the range of 0 m minimum and 30 m maximum. 7- WALK TEST Area A Area B H Manual H Auto H2 Manual H2 Auto V Auto...
  • Page 12: Specifications

    OPTEX SECURITY SAS (FRANCE) TEL:+-909-993-5770 TEL:+33-437-55-50-50 (ISO 9001 Certified) Tech:(800)966-7839 URL:http://www.optex-security.com (ISO 14001 Certified) URL:http://www.optexamerica.com 5-8-2 Ogoto Otsu Shiga 520-00 OPTEX (EUROPE) LTD. (UK) OPTEX SECURITY Sp.z o.o. (POLAND) JAPAN TEL:+44-628-63000 TEL:+48-22-598-06-55 TEL:+8-77-579-8670 URL:http://www.optexeurope.com URL:http://www.optex.com.pl FAX:+8-77-579-890 URL:http://www.optex.co.jp/e/ - 2 -...