Specifications; Detection Area Diagram - Optex Virtual Loop Installation Instructions Manual

Vehicle detection sensor for gate
Table of Contents

Advertisement

10

Specifications

10-1
Specifications
Detection method
Frequency
Response
Supply voltage
Power consumption
Spec
Output
Pulse time duration
Input
Application
Detectable vehicle speed
Fine tuning presence
Close range sensitivity
Side approach detection [s]
Device
Vibration sensitivity
setting
Sensitvity boost timer [s]
Relay Response time
Presence detection timer [min]
Slide gate cancellation
Standard
operation
mode
Indicator
Smartphone
app
connection
mode
Ambient Temperature
Operating Ambient Humidity
Degree of Protection
Installation Location
Installation Height
Sensor Angle Adjustment
Accessories
<Notice>
Please note that we are not responsible for any damage that occurred when the equipment is operated or installed improperly.
10-2

Detection Area Diagram

Top view
1
1m
0
1
0
1
2
Installation height 0.5m(20'' ), Sensitivity: 4, Detection area check mode
* Under normal operation, the detection area by an actual vehicle may be smaller.
Name
Model
1
2
Delay [s]
Hold timer [s]
Mode
Type
Spec
Mode
Detection range
Main sensitivity
Sensitvity boost
On / Off
Detection operation
Wake up
Sensor reset
Setting
Detection operation
Area check
Calibration
Weight
3m
8m setting
3
4
5
6
Vehicle Detection Sensor (Surface mount)
Microwave ( FMCW)
Microwave︓24GHz、BLE communication︓2.4GHz
12 to 24VAC/DC
Heater enabled︓Up to 300mA、Heater disabled︓Up to 90mA( at 24V )
Non-voltage solid state relay output 30VDC 0.3A or less (resistance load) (N.O. / N.C.)
Non-voltage mechanical relay output 30VDC 1A or less (resistance load) (N.O. / N.C.)
Off / 0.5 / 1 / 2 / 3 / 4
Off / 0.5 / 1 / 2 / 3 / 10 / 30 / 60
Detection / Pre-detection / Mask
Holding / Pulse IN / Pulse OUT
150ms / 250ms / 500ms / 1s
N.O. contact Non-voltage relay Input
On resistance 100Ω or less, Off resistance 200kΩ or more,
Internal pull-up voltage: approx. 3.3V
Link(OR gate) / Link (AND gate) / Inhibit / Wake
Barrier-Activation,Protection / Slide gater-Activation,Protection /
Swing gater-Activation,Protection, Shadow
2 to 35km/h (1.2 to 22 mi/h)
1.5m(7ft.) to 8.0m(26ft.) *0.5m(20in.) pitch
Off / 2.5 / 5 / 10 / 30 / 60 / 120
Off / Low / Middle / High
Off / Low / Middle / High
Off / 0.5 / 1 / 2 / 3 / 4 / 5 / 10 / 20 / 40
5 / 15 / 60 / 180 / Infinity
Switchable (with the smartphone App or by holding a magnet close to the unit)
Standby : Solid green, Detected : Solid red, Bad environment : Solid purple,
Calibration uncompleted : Solid blue
Wake up : Solid blue for 3 seconds
Completed reset : Blinking blue (Fast) for 2 seconds
Stanby : Blinking green(slow), Detected : Blinking yellow(slow),
Bad environment : Blinking purple(slow), Calibration uncompleted : Blinking blue(slow)
Stanby : Blinking green(slow), Pre-detected : Blinking yellow(slow),
Detected : Blinking red(slow)
In process : Blinking Blue & Green, Error Unstable : Blinking Red & Yellow(Fast),
Error High reflection : Blinking Red & Blue(Fast), High reflection : Blinking Purple(for 10s)
-30 to 50℃ (-22 to 122 °F)
95% max. ( no condensation )
Indoor / Outdoor
500mm(20in.) ( from the ground to the bottom of the unit)
Left and right︓±96°(3°pitch )
600g (21oz) ( Including accessories)
4pcs attached screws (2pcs Metric coarse thread M4x12, 2pcs Tapping screw 4x20),
Quick reference guide
Specifications are subject to change without notice for improvement.
Side view
3
2
1
0
7
8
9
0
-37-
OVS-02GT
MIN 500ms
Level 1 to 7
Level 1 to 7
Level 1 to 7
Level 1 to 4
Off / On
IP66 / NEMA4
1m
3m
1
2
3
4
5
[Unit: m (1m ≈ 3.3ft.)]
8m setting
6
7
8
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ovs-02gt