CX-702 / CX-702V
CX-702V Only
*The CX-702 is UL Listed per UL639, Intrusion-Detection Units.
*The CX-702V has not been investigated by UL.
OPTION
CA-1W : Wall Mount Bracket: adjustable ±45°(Horizontally), 0-20°(Vertically downwards)
CA-2C : Ceiling Bracket: adjustable ±45°(Horizontally), 0-20°(Vertically downwards)
Never repair or modify product. It may cause accident, fire hazard or electric shock.
When damage has occured to the product, i.e. water logged, abnormal things inside product, overheating or smoking, strange smells etc., immediately stop using product and contact your supplier. Otherwise, continued use in such condition may cause electric shock or fire hazard.
Mount securely. A falling product may cause injury.
**ATTENTION**
The specified detection area can be achieved by mounting the unit at a height of 8ft.(2.4m). Mounting at a lower or higher height may reduce the area of coverage.
Power wires should not exceed the following lengths.
CX-702 | CX-702V | |||
WIRE SIZE | 12V | 14V | 12V | 14V |
AWG 22 (0.33mm2) | 1700ft. (520m) | 3700ft. (1130m) | 3700ft. (360m) | 2520ft. (770m) |
AWG 20 (0.52mm2) | 2690ft. (820m) | 5830ft. (1780m) | 1830ft. (560m) | 4000ft (1220m) |
AWG 18 (0.83mm2) | 4290ft. (1310m). | 9350ft (2850m) | 2950ft. (900m) | 6430ft. (1960m) |
When using two or more units on one wire, the maximum length is obtained by dividing the maximum wire length listed above by the number of units used.
* UL requires CX-702 to be connected to a UL listed power supply capable of providing a nominal input of 12VDC 11mA(max.) and battery standby time of 4 hours.
* For UL Listed systems, do not connect field wiring more than 25ft. to Alarm Memory, and DL terminals.
* The equipment shall be installed in accordance with the National Electrical Code, NFPA 70.
The CX-702 is designed to provide ideal detection areas for different patterns ranging from 40ft.(12m) to 70ft.(21m) Wide Angle, and 80ft.(24m) to 150ft.(45m) Long Range. The following adjustments will provide ideal detection areas for each of these requirements.
Always conduct a walktest after changing the position of this switch to ensure the detector is still providing optimum coverage.
When the "4" is selected, the detector's sensitivity may seem sluggish. It is therefore important to always conduct a walktest to ensure that the desired coverage is given.
Do not use pulse count 4 for Long Range detection.
CONTROL VOLTAGE SIGNAL
POSITIVE | NEGATIVE | |
System Armed | OPEN or +5~16VDC | 0~1VDC(grounded) |
System Disarmed | 0~1VDC(grounded) | OPEN or +5~16VDC |
Operation
If the unit triggered during armed period, when the system is disarmed, LED will remain lit to confirm that it reported an alarm.
Reset
Alarm Memory resets automatically when system is re-armed.
POSITIVE : Leave AM Jumper as it is.
NEGATIVE : Cut AM Jumper as shown.
PROBLEM | PROBABLE CAUSE | REMEDY |
LED does not light. | Improper power supply voltage (disconnection, low voltage). | Correct supply voltage to 9.5 - 16V DC. |
Improper detection area. | ||
LED switch is OFF. | Turn on the switch. | |
Improper polarity to detector. | Switch positive and negative at terminal. | |
LED lights even though no person within area. | Moving object within area (curtain, wall hanging, etc.). | Remove the souces from the detection area. |
Temperature of object within area changing rapidly (heater, air conditioning, etc.). | Remove object from the detection area. | |
LED lights but signal is not sent. | Relay contact is stuck or damaged due to overloading. | Check load of output. The unit needs repair or replacement. |
LED continues to light | Faulty wiring. | Wire correctly. |
Poor connection of alarm memory. | Reconnect wire. | |
Wrong control voltage from panel. | Must be 0-1V DC(grounded) |
NOTE
These units are designed to detect movement of an intruder and activate an alarm control panel.
Being only part of a complete alarm system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion.
These products conform to the EMC Directive 89/336 EEC.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Optex CX-702, CX-702V - Passive Infrared Detector Manual