Counters
Counter inputs
- logic inputs
- logic channels
- alarms
- errors
- Modbus-Flag (signal via serial interface)
Counter
30Hz max.
frequency
Weighting
The count pulses can be evaluated (weighted). A down counter can be imple-
mented by entering a negative weighting (e.g. weighting factor -1).
Each count change can be documented with an entry in the event list. The
new count is attached to the message.
Integrators
Integrator
- analog inputs 1— 3 (6)
inputs
Integrator
- sec, min, hr and day
time base
Weighting
You can also enter a weighting for the integrators.
Weighting
- flow measurement
example
- input signal from 0 — 20mA (corresponds to 0 — 1000 l/sec)
- time base 1sec
- weighting 0.001
- display of the integration value (quantity) in m³
Minimum size
Entering a threshold value (amount of threshold value) has the effect that inte-
of input signal
gration takes place only when the value has been exceeded. No integration
will occur on falling below the value. The advantage of integration with a
threshold value larger than 0 is that possible noise from a transducer can be
suppressed in this way.
Timers
The timer will count for as long as the selected logic input or one of the digital
signals is closed (set). The time can be displayed in sec, min, hr and days.