Specifications

The following specifications apply to all MillipaK controllers.

Power Configurations

At present the MillipaK 4Q controller is available in the following power configurations:
Housing
HP Large
HP Large
Table 14: Power Configurations
All the MillipaK 4Q range of controllers operate from 24-48v batteries.
WARNING: The pump soft start option, when fitted, is NOT current limited and
care should be taken not to exceed the maximum current specified by
the controller rating.

EMC standards

All MillipaK variants are tested to and conform to EN12895.
Socket B protection
All user connections on socket B are protected against indefinite short circuit to battery minus and
battery positive.

Contactor drive ratings

All contactor drives are rated at 3A peak (10s) and 1.5A continuous. All the drives have reverse
battery connection protection, inbuilt freewheel diode and are internally protected against short
circuit.

Analogue Input Impedance

The two analogue inputs are internally pulled up to +12v via a 12k resistor. This is primarily
designed for use with 5k potentiometers, but may also be used with suitable voltage sources.

Digital Input Impedance

The digital inputs are internally pulled up and are active LOW. They therefore must be connected
to battery minus to operate a function. Maximum resistance to battery minus to operate is
500ohms.
MillipaK 4QPM Controller Manual
Armature
Soft Start Option
180A
100A Soft Start
330A
100A Soft Start
Page 71
Specifications
13/08/03