Features
______________________________________________________________________________

Alarm Buzzer

The Alarm Buzzer function is used to drive a warning buzzer when the vehicle moving in
different conditions. The function works by activating the Buzzer output when:
Mode 'OFF'
1) The buzzer will not sound at any time if the Buzzer contactor drive output is configured.
Mode 'Rol'
1) The Reverse Switch is active or vehicle is travelling in reverse – continuous output.
2) The vehicle is moving without a direction selected – pulsed output.
Mode 'All'
1) The Forward Switch is active or vehicle is travelling in forward – continuous output.
2) The Reverse Switch is active or vehicle is travelling in reverse – continuous output.
3) The vehicle is moving without a direction selected – pulsed output.
Alarm Buzzer
Calibrator Menu Reference:
Off
Rol
MillipaK 4QPM Controller Manual
Power Up
12.16
Options
Default
All
Rol
Optional Features/Reverse Buzzer