Cutback Speeds - Sevcon MillipaK 4QPM Manual

Table of Contents

Advertisement

Features
______________________________________________________________________________

Cutback speeds

There are 2 cutback switch inputs as standard. Each one has an associated personality to adjust the
maximum % on when the switch is active. When both switches are active together, the lower
speed is selected. The cutback speed inputs are usually normally closed so that a wire off type
fault or bad connection initiates a lower speed.
Cutback Speed 1
Calibrator Menu Reference:
Minimum
Maximum
0%
100%
Cutback Speed 2
Calibrator Menu Reference:
Minimum
Maximum
0%
100%
MillipaK 4QPM Controller Manual
Immediate
6.01
Step Size
Typical Value
1%
100%
Immediate
7.01
Step Size
Typical Value
1%
100%
Standard Features/Cutback Speeds