Fault Clearance - Sevcon MillipaK 4QPM Manual

Table of Contents

Advertisement

______________________________________________________________________________
ID
Fault
10
Two Direction Fault
11
Sequence Fault
12
Low Battery Fault
13
High Battery Fault
High Battery Fault with
14
Line Contactor Open
Configuration Range
15
Fault
Configuration CRC
16
Fault
Line Contactor Welded
17
Fault
Line Contactor did not
18
Close Fault
Lower MOSFETs Short
19
Circuit
20
-
21
MOSFET Off
22
MOSFET On
Upper MOSFETs Short
23
Circuit
24
Drive 2 Off
25
Drive 2 On
26
Drive 1 Off
27
Drive 1 On
Table 11: Fault Numbers and Descriptions

Fault Clearance

Any fault indication will be cleared by re-initiating the start sequence after the cause of the fault
has been removed.
MillipaK 4QPM Controller Manual
Description
Two directions selected together.
Direction or FS1 switch closed at power up.
Battery voltage is too low.
Battery voltage is too high.
Battery voltage is too high before the line
contactor is closed
A personality is out of range.
The personality CRC is incorrect
Line contactor is welded.
Line contactor is open circuit.
Short circuit on Q2/Q4 Armature MOSFETs
detected.
Reserved for future use
MOSFETs did not pulse during power on
failsafe checks (failsafe circuit enabled).
MOSFETs pulsed during power on failsafe
checks (failsafe circuit disabled).
Short circuit Q1/Q3 Armature MOSFETs
detected.
Contactor 2 did not pulse during power on
failsafe checks (failsafe circuit enabled).
Contactor 2 pulsed during power on failsafe
checks (failsafe circuit disabled).
Contactor 1 did not pulse during power on
failsafe checks (failsafe circuit enabled).
Contactor 1 pulsed during power on failsafe
checks (failsafe circuit disabled).
Page 68
Fault Finding
Flash Fault
2
2
7
7
7
1
1
4
4
3
-
0
0
3
0
0
0
0
13/08/03