Safe Operating Area (Soa) - Sevcon MillipaK 4QPM Manual

Table of Contents

Advertisement

Controller Protection
______________________________________________________________________________

Safe Operating Area (SOA)

The controller's current may be limited at high and/or low duty cycles depending on its current
and voltage specification. This is to reduce the thermal stress on the power components in order to
increase long term reliability. See Figure 7.
The "Safe Operating Area" is a characteristic of the MOSFETs and Freewheel Diodes which
make up the power-frame. The MOSFET SOA restricts current at high duty cycles on all
configurations, and the Diode SOA tends to restrict the current at lower duty cycles on lower
voltage applications.
For most applications SOA will have little or no effect on the operation of the controller. Its effect
is more significant in protecting the controller against adverse loads such as damaged motors and
static test rigs.
Figure 7: SOA Characteristic
MillipaK 4QPM Controller Manual
24-48V Controllers
100
90
80
70
60
50
40
30
20
10
0
0
20
40
60
% On
Page 59
Safe Operating Area
80
100
13/08/03