Features
______________________________________________________________________________

Seat Switch

If the seat switch is opened and the seat switch timer has timed out during drive the controller will
stop pulsing and a seat fault will be indicated. Before drive can be restarted the seat switch must
be closed, and FS1 and the direction switch must be recycled through neutral. Note the start
sequence for drive requires that the seat switch is closed and both the direction and FS1 switches
are in the neutral position simultaneously before drive can be initiated. The time period is
programmed by means of the Calibrator (Seat Switch Delay). As a setup menu option the seat
switch can also inhibit pump operation if required.
Seat Delay
Calibrator Menu Reference:
Minimum
Maximum
0.1S
5.0S
Seat Cuts Pump
Calibrator Menu Reference:
Options
OFF
MillipaK 4QPM Controller Manual
Step Size
0.1S
ON
Immediate
10.01
Typical Value
5.0S
Power On
12.04
Typical Value
OFF