Operating frequency (Max.
frequency= full-scale value)
1:
Reference frequency (Max.
frequency =full-scale value)
2: Output current (2 times inverter
rated current=full-scale value)
3:
Output voltage (1.5 times
inverter rated voltage=full-scale
value)
4: Output capacity (2 times motor
rated capacity=full-scale value)
5: Output torque (2.5 times motor
rated torque=full-scale value)
6:
Reference torque (2.5 times
motor
rated
torque=full-scale
value)
7: PID feedback value
8: PID reference value
9: PID output value
10: AI1
11: AI2
12: PFI
 Option 43 and 44 are effective to the models in parallel only in the table of analog output definition.
 Analog output has the following three types:
Analog output
0~10V or 0~20mA
 Adjusting the gain and bias can change the measuring range and correct the zero point. The calculation
formula is: Y=X×gain+bias(X is any item in the table of analog output functions).
F6-22
PFI frequency corresponding to 100%
F6-23
PFI frequency corresponding to 0%
Settting
0~50000Hz
range
F6-24
Setting
0.000~10.000s
range
 The PFI function converts the input pulse frequency to a percentage value and filters it, as shown below.
PFI can be used as the frequency reference for cascade synchronous control, or as the PID feedback for
constant line speed control.
13: UP/DOWN value
14:
DC
(1000V=full-scale value)
15:
Reference frequency after
accel/decel
frequency=full-scale value)
16: PG detection frequency (Max.
frequency=full-scale value)
17:
Counter
count=full-scale value)
18:
Count percentage (setpoint
count=full-scale value)
19: Arithmetic unit 1 output
20: Arithmetic unit 2 output
21: Arithmetic unit 3 output
22: Arithmetic unit 4 output
23: Arithmetic unit 5 output
24: Arithmetic unit 6 output
25: Low-pass filter 1 output
26: Low-pass filter 2 output
27:
Analog multiple switching
output
28: Comparator 1 digital setting
Analog output
Output
quantity
2~10V or 4~20mA
PFI filtering time
29: Comparator 2 digital setting
link
voltage
30:
setting
31:
(Max.
setting
32:
setting
33:
error
(setpoint
setting
34:
setting
35:
setting
36: PC analog 1
37: PC analog 2
38: Factory output 1
39: Factory output 2
40:
41:
potentiometer)
42: Count value of counter 243:
Temperature of radiator 1
44: Temperature of radiator 2
43, 44: Full amplitude based on
100℃
Analog output
Output
quantity
Based on 5V or 10mA
Default
Default
Default
6 Parameter Description
Arithmetic unit 1 digital
Arithmetic unit 2 digital
Arithmetic unit 3 digital
Arithmetic unit 4 digital
Arithmetic unit 5 digital
Arithmetic unit 6 digital
Output
frequency(for
factory use)
Keypad POT value(POT:
Output
quantity
10000Hz
Change
0Hz
Change
0.100s
Change
91