X1 Counter UP command
32 Designated count reach
69 Designated count 2 reach
31 Setpoint count reach
 F9-16: count after combining input pulse and combine one count pulse via F9-16 pulse.
 Related monitored parameters include FU-15, FU-34 and related analog outputs include 17 and 18. They
can be connected to the analog output, arithmetic unit and PID feedback. Their functions are shown as
below.
FU-15
Counter count
F9-17
Meter-counter input command select
Setting
Refer to the table of digital output functions in Section 6.6.
range
F9-18
Setting
0~65535m
range
F9-19
Meter-counter pulse number per meter
Setting
0.1~6553.5
range
F9-17:
 When digital outputs 34~46 are selected, the input signal is affected by F4-11.
 Selecting digital outputs 57 and 58 can realize high-speed meter counting, with the highest input
frequency reaching 300kHz.
 Selecting the digital output 59 can also realize high-speed meter counting, with the highest input
frequency reaching 50kHz.
 The sampling time is 1ms when other digital outputs are selected.
When FU-16 reaches F9-18, the digital output 33 becomes valid.
When the digital input 52 is valid, FU-16 is cleared.
F9-20
1
2
3
÷
F9-14
Setpoint count
F9-13
Counter preset value
Meter-counter setpoint length
Zero-servo control
6
4
5
7
Analog output 18: Count percentage
FU-34 Counter error
÷
F9-14
Setpoint count
Default
Default
Default
Default
6 Parameter Description
8
9
10
11
Analog output 17:
Counter error
0
Change
1000m
Change
100.0
Change
0
Change
×
105