Senlan Hope800 Series Manual page 57

High-performance vector control inverter
Table of Contents

Advertisement

No.
Name
Comparator 1 in-phase
FE-00
input
Comparator 1
FE-01
opposite-phase input
FE-02
Comparator 1 config
Comparator 1 digital
FE-03
setting
FE-04 Comparator 1 error band 0.0~100.0%
Comparator 1 output
FE-05
select
Comparator 2 in-phase
FE-06
input select
Comparator 2
FE-07
opposite-phase input
select
FE-08
Comparator 2 config
Comparator 2 digital
FE-09
setting
FE-10 Comparator 2 error band 0.0~100.0%
Comparator 2 output
FE-11
select
Logic unit 1 input 1
FE-12
select
Logic unit 1 input 2
FE-13
select
FE-14
Logic unit 1 config
Logic unit 1 output
FE-15
select
Logic unit 2 input 1
FE-16
select
Logic unit 2 input 2
FE-17
select
FE-18
Logic unit 2 config
Setting range
Same as F6-14
Same as F6-14
Units digit: selects the functions
0: >
1: <
2: =
4: Output always 1
Tens digit: whether to take absolute value
0: No
1: Yes
Hundreds digit: selects the protection function
for comparator output
0: No action
1: The motor continues running with an alarm
2:
The inverter coasts to a stop due to
fault(Er.Co1 or Er.Co2 displayed)
-100.0~100.0%(corresponding to analog output
28)
Same as F4-00
Same as F6-14
Same as F6-14
Same as FE-02
-100.0~100.0%(corresponding to analog output
29)
Same as F4-00
Same as F5-00
0: AND
1: OR
3: NOR
4: XOR(≠)
6: Output=input 1
8:
Output≡1
9:
trigger
Same as F4-00
Same as F5-00
Same as FE-14
3: ≠
5: Output always 0
2: NAND
5: XNOR(=)
7: Output= ~ input 1
Output≡0
10:
R-S
5 Parameter table
Default Change Page
0
121
0
121
005
121
122
50.0%
122
5.0%
0
122
0
122
0
122
005
122
122
50.0%
122
5.0%
0
122
0
123
0
123
9
123
0
123
0
123
0
123
9
123
53