6 Parameter Description
Setting
-290.0~290.0%(motor rated torque=100%)
range
F3-16
Torque control speed limit input select
Setting
0: Determined by reference frequency
range
F3-17
Torque control speed forward limit
Setting
0.00Hz~F0-07
range
F3-18
Torque control speed reverse limit
Setting
0.00Hz~F0-07
range
F3-19
Torque reference UP/DOWN time
Setting
0.000~10.000s. This time is the time over which the torque rises from zero to 250% of
range
motor rated torque.
Speed/torque control switching delay
F3-20
Setting
0.001~1.000s
range
The torque control function can control the motor torque directly. It can be used for open-loop tension
control, load balancing control, etc. Upon receiving the stop command in torque control mode, the
inverter will switch to the speed control mode and stop.
Torque control is only applicable to vector control, and PG vector control is recommended for torque
control at low speeds or in generating state.
F3-13=0 means that the digital input 45 can switch from speed control to torque control. Refer to page 74.
F3-16 selects the source for limiting the speed for torque control.
F3-19 is used to reduce the sudden change of the torque command. If the motor vibrates in torque
control mode, increasing F3-19 can be considered.
In torque control mode, the REV indicator on the keypad shows the direction of the operating frequency.
F3-21
Setting
0.01~5.00s(only valid for vector control)
range
F3-22
Setting
50.0~150.0%(only valid for vector control)
range
F3-23
Setting
0~50%(only valid for vector control)
range
F3-24
Flux-weakening regulator integral time
Setting
0.010~3.000s(only valid for vector control)
range
F3-21 ensures that the motor has a full pre-excitation and enough starting torque. The pre-excitation time
is normally 0.1~2.0s, and the larger the motor capacity, the longer the time.
F3-22: its value is better to be below the flux-weakening point. Either overhigh or overlow setting would
76
time
Pre-excitation time
Flux density
Low-speed flux boost
Default
0
1: Determined by F3-17 and F3-18
Default
5.00Hz
Default
5.00Hz
Default
0.020s
Default
0.050s
Depends
Default
on mode
Default
90.0%
Default
Default
0.150s
○