6 Parameter Description
Menu
Parameter
code
group No.
F0
0(00H)
F1
1(01H)
F2
2(02H)
F3
3(03H)
F4
4(04H)
 The data transmitted in communication are 16-bit integers. The minimum unit can be seen from the
position of the radix point of the parameter. For example, the minimum unit of F0-00 is 0.01Hz,
therefore, the data 5000 transmitted in communication represents 50.00Hz.
 Table of communication command variables
Modbus
Name
address
Main control
3200H
word
Communication
reference
3201H
frequency
PC analog 1
3202H
PC analog 2
3203H
Extended control
3204H
word 1
Extended control
3205H
word 2
Extended control
3206H
word 3
Extended control
3207H
word 4
Extended control
3208H
word 5
EEPROM
3209H
write-in
Note: Digital inputs 37, 38 and 39 are only used for terminal control. They are invalid in communication
control.
130
Menu
Parameter
code
group No.
F5
5(05H)
F6
6(06H)
F7
7(07H)
F8
8(08H)
F9
9(09H)
Change
Bit 0: ON/OFF1(run on rising edge. 0: stop)
Bit 1: OFF2(0: coast stop)
Bit 2: OFF3(0: emergency stop)
Bit 3: Driving lockout(0: driving lockout)
Bit 4: Accel/decel enabled(0: accel/decel disabled)
Bit 5: Reserved
Bit 6: Reserved
Bit 7: Fault reset(on rising edge)
Bit 8: Jog forward
Bit 9: Jog reverse
Bit 10: Reserved
Bit 11:
Bit 12: PC digital 1(used for programmable unit)
Bit 13: UP
Bit 14: DOWN
Bit 15: PC digital 2(used for programmable unit)
Non-negatives (unit: 0.01Hz). Used as the frequency
reference after multiplied by FF-08.
Range: -32768~32767
Except position control, set other situations within
-10000~10000.
Bits 0~15 correspond to digital inputs 1~16
Bits 0~15 correspond to digital inputs 17~32
Bits 0~15 correspond to digital inputs 33~48
Bits 0~5 correspond to digital inputs 49~55, other bits are
reserved.
Reserved
When "1" is written to this address, the parameters in the
inverter RAM will be written in EEPROM.
Menu
Parameter
code
group No.
FA
10(0AH)
Fb
11(0BH)
FC
12(0CH)
Fd
13(0DH)
FE
14(0EH)
Description
Reference reversion(1:
reversed, 0: not reversed)
Parameter
Menu code
group No.
FF
15(0FH)
Fn
16(10H)
FP
17(11H)
FU
18(12H)
Communication
50(32H)
variables
reference frequency