Senlan Hope800 Series Manual page 85

High-performance vector control inverter
Table of Contents

Advertisement

F4-08
Mode
2-wire mode 3
3
(start, stop)
3-wire mode 1
(FWD, REV, stop)
4
Digital input 37
needed
3-wire mode 2
(Run, direction,
5
stop)
Digital input 37
needed
2-wire mode 4
6
(single pulse start,
stop)
In 1-wire mode or 2-wire mode 1 and 2 under the terminal control mode, if the stop command comes
from other sources and causes the inverter to stop, then the stop command must be given before the run
command in order to restart the inverter.
In 3-wire mode 3 and 3-wire mode, the run button is invalid if the normally-closed stop button is open.
Even if the run direction has been determined, it is still restricted by F0-09(direction lock)
If the terminal command doesn't contain the direction information, the run direction will be determined
by the polarity of the reference frequency channel.
Danger
: When the run signal exists and Fb-26=1 (default value), the inverter will self start.
F4-09
Input terminal logic 1(positive & negative)
Ten thoudands digit: X5
Setting
Tens digit: X2
range
0: Positive logic, valid when circuit is closed and invalid when circuit is open.
1: Negative logic, invalid when circuit is closed and valid when circuit is open.
F4-10
Input terminal logic 2(positive & negative)
Hundreds digit: REV
Setting
0: Positive logic, valid when circuit is closed and invalid when circuit is open.
range
1: Negative logic, invalid when circuit is closed and valid when circuit is open.
F4-11
Digital input terminal anti-jittering time
Setting
0~2000ms
range
This parameter determines the anti-jittering time for the digital input signal. Those signals with their
duration less than the anti-jittering time will be ignored.
Logic
B1: Run button(normally-open)
B2: Stop button(normally-closed)
Note: The run direction is determined by the
direction of the reference frequency.
B1: Stop button(normally-closed)
B2: FWD button(normally-open)
B3: REV button(normally-open)
B1: Stop button(normally-closed)
B2: Run button(normally-open)
S: Direction switch. When it is valid, the
motor runs reverse.
B1: FWD button(normally-open)
B2: REV button(normally-open)
Thoudands digit: X4
Units digit: X1
Tens digit: FWD
6 Parameter Description
B1
B2
B1
B2
B3
Default
00000
Hundreds digit: X3
Default
000
Units digit: X6
Default
10ms
Diagram
P12
CMX
Internal virtual
FWD terminal
Internal virtual
REV terminal
COM
P12
CMX
Stop command
(3-wire mode)
Internal virtual
FWD terminal
Internal virtual
REV terminal
COM
3-wire stop command
Internal virtual FWD
terminal
Internal virtual REV terminal
Internal virtual FWD
terminal
Internal virtual REV
terminal
Change
×
Change
×
Change
81