When F9-09 is not equal to zero, the actual rising time will vary randomly within a certain range, while
the wobble period remain unchanged. The function of random wobble can prevent the stacking of some
high-elasticity fibers when they are wound.
F9-10 selects the wobble restart mode.
Digital input 54:
frequency is disabled and the inverter runs at the center frequency.
Digital output 30: If the center frequency or wobble amplitude is set too high and the wobble frequency
goes beyond the upper- or lower-limit frequency, the wobble amplitude will be reduced automatically to
make the wobble frequency fall within the range between upper- and lower-limit frequency, as shown
below.
Output frequency
Upper-limit
frequency
Center
frequency
Lower-limit
frequency
0
digital output 30
The wobble frequency is only valid in stable operation. If the center frequency changed during the wobble
operation, the wobble frequency becomes invalid automatically until the stable operation resumes.
When swing frequency function is recommended, F2-09 (vibration damping) should be set to 0.
F9-11
Setting
Refer to the table of digital output functions in Section 6.6.
range
F9-12
Counter DOWN command select
Setting
Refer to the table of digital output functions in Section 6.6.
range
F9-13
Setting
0~65535
range
F9-14
Setting
F9-15~65535
range
F9-15
Setting
0~F9-14
range
F9-16
Counter frequency-dividing coefficient
Setting
1~65535
range
If F9-00=1, the inverter runs at the preset frequency; if F9-00=2, the wobble
Counter UP command select
Counter preset value
Setpoint count
Designated count
6 Parameter Description
Default
57
Default
58
Default
0
Default
10000
Default
0
Default
1
Time
Time
○
Change
○
Change
○
Change
○
Change
○
Change
○
Change