1.
Overview
Specifications
Specifications
Table 1
shows the specifications of the power synchronized unit and the AC sensor unit.
Table 1
Specifications
Dimensions (W D H)
Weight
Power
Maximum power requirements
Maximum heat generation
Connection interface
Number of con-
nectable
devices
Cable length
Conditions to detect AC output
Support for a duplicated configuration
Environmental condition
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide (Power Synchronized Unit)
Item
Power synchronized unit
AC sensor unit
Power synchronized unit
AC sensor unit
Voltage
Phase
Frequency
AC100 - 120V
AC200 - 240V
AC100 - 120V
AC200 - 240V
For ETERNUS DX/AF storage systems
For AC detection
Basic
Server UPS unit
Maximum (when AC sensor units are
connected)
Basic
ETERNUS DX/AF
Maximum (when a cascade connec-
tion is used)
Between a power synchronized unit
and an AC sensor unit (total)
Between a power synchronized unit
and the ETERNUS DX/AF
Between power synchronized units
Power consumption
Voltage
Phase
Temperature
Humidity
Copyright 2019 FUJITSU LIMITED
0.1A or less AC output for one second or
22
Specifications
440 230 40 (mm) [1U]
100 150 40 (mm) [1U]
4.0kg
1.3kg
AC100 - 120V, AC200 - 240V
Single
50Hz/60Hz
3W
7W
11kJ/h
26kJ/h
RS232C 4
AC sensor 2
2
16
4
8
Max. 100m
Max. 5m
Max. 10m
more is detected.
AC100V / AC200V
Single
Yes
5 - 40C (during operation)
0 - 50C (during non-operation)
20 - 80%RH (during operation)
8 - 80%RH (during non-operation)
P3AM-8012-14ENZ0