Basic safety instructions
10
2.3
Workplace safety
When working on and with the device:
‣
Wear the required protective equipment according to federal or national regulations.
With separable probe rods, medium may penetrate the joints between the individual parts
of the rod. This medium may escape when the joints are loosened. This can cause injuries
in the case of dangerous (e.g., aggressive or toxic) media.
‣
When loosening the joints between the individual parts of the probe rod, wear
appropriate protective equipment according to the medium.
2.4
Operational safety
Risk of injury!
‣
Operate the device only if it is in proper technical condition, free from errors and faults.
‣
The operator is responsible for the interference-free operation of the device.
Modifications to the device
Unauthorized modifications to the device are not permitted and can lead to unforeseeable
dangers:
‣
If modifications are nevertheless required, consult with the manufacturer.
Repair
To ensure continued operational safety and reliability:
‣
Carry out repairs on the device only if they are expressly permitted.
‣
Observe federal/national regulations pertaining to the repair of an electrical device.
‣
Use only original spare parts and accessories from the manufacturer.
Hazardous area
To eliminate danger to persons or the installation when the device is used in the
hazardous area (e.g. explosion protection, pressure vessel safety):
‣
Check the nameplate to verify whether the ordered device can be put to its intended
use in the hazardous area.
‣
Observe the specifications in the separate supplementary documentation, which is an
integral part of this manual.
2.5
Product safety
This measuring device is designed in accordance with good engineering practice to meet
state-of-the-art safety requirements, has been tested, and left the factory in a condition in
which it is safe to operate. It meets the general safety standards and legal requirements.
NOTICE
Loss of degree of protection by opening of the device in humid environments
‣
If the device is opened in a humid environment, the degree of protection indicated on
the nameplate is no longer valid. This may also impair the safe operation of the device.
2.5.1
CE mark
The measuring system meets the legal requirements of the applicable EU directives. These
are listed in the corresponding EU Declaration of Conformity together with the standards
applied.
The manufacturer confirms successful testing of the device by affixing to it the CE mark.
Levelflex FMP53 PROFIBUS PA
Endress+Hauser