Minor Faults and Alarms
■
LED Operator Display
Cause
Address outside the specified address
range
LED Operator Display
Cause
Communication wiring is faulty, there
is a short circuit, or something is not
connected properly.
Programming error on the master side
Communication circuitry is damaged.
YASKAWA ELECTRIC TOBP C730600 24D 1000-Series Option SI-S3/V, SI-S3/T Installation Manual
9 Fault Diagnosis and Possible Solutions
Setting Address Error
AEr
CANopen Option is set to an address outside the allowable setting range.
⇒ Set F6-35 to an address within the specified range.
Serial Communication Transmission Error
CALL
Communication has not yet been established.
Check for wiring errors.
⇒ Correct the wiring.
⇒ Remove and ground shorts and reconnect loose
wires.
⇒ Check communications at start-up and correct
programming errors.
Perform a self-diagnostics check.
⇒ Replace the drive if the fault continues to occur.