F18
3.
For setting access group, please refer to
Enable Holiday function: Select All Groups on the Access Groups interface and press M/OK. Then,
4.
select Edit on the Access Groups interface and press M/OK, and select Include Holidays and press
M/OK to turn the access group ON.
Note: If a holiday is to be valid for all users, allocate all users to the same group or enable the Include
Holidays for all access groups.

Combined Verification

Access groups are arranged into different door-unlocking combinations to achieve multiple verifications
and strengthen security.
In a door-unlocking combination, the range of the combined number N is 0 ≤ N ≤ 5 and the number of
members N may all belong to one access group or may belong to five different access groups.
Select Combined Verification on the Access Groups interface and press M/OK to configure the
combined verification setting.
On the combined verification interface, select the Door-unlock combination and press M/OK to be set, and
press the up and down arrows to input the combination number, and then press M/OK.
For Example:
If the Door-unlock combination 1 is set as (01 03 05 06 08). It indicates that the unlock combination
1 consists of 5 people and all the 5 individuals are from 5 groups, namely, AC Group 1, AC Group 3, AC
Group 5, AC Group 6, and AC Group 8, respectively.
P a g e
| 53
9.4 Access Group Settings
Copyright©2023 ZKTECO CO., LTD. All rights reserved.