NEC 78K0/KB1+ Preliminary User's Manual page 262

8-bit single-chip microcontrollers
Table of Contents

Advertisement

(5) Data frame length during continuous transmission
When data is continuously transmitted, the data frame length from a stop bit to the next start bit is extended by
two clocks of base clock from the normal value. However, the result of communication is not affected because
the timing is initialized on the reception side when the start bit is detected.
Figure 12-27. Data Frame Length During Continuous Transmission
Start bit
FL
Where the 1-bit data length is FL, the stop bit length is FLstp, and base clock frequency is f
expression is satisfied.
FLstp = FL + 2/f
XCLK6
Therefore, the data frame length during continuous transmission is:
Data frame length = 11 × FL + 2/f
262
CHAPTER 12 SERIAL INTERFACE UART6
1 data frame
Bit 0
Bit 1
FL
FL
XCLK6
Preliminary User's Manual U16846EJ1V0UD
Bit 7
Parity bit
Stop bit
FL
FL
FLstp
Start bit of
second byte
Bit 0
Start bit
FL
FL
, the following
XCLK6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ypd78f0101hYpd78f0102hYpd78f0103h

Table of Contents