CHAPTER 11 SERIAL INTERFACE UART0 (
Minimum permissible data frame length: FLmin = 11 × FL −
Therefore, the maximum receivable baud rate at the transmission destination is as follows.
BRmax = (FLmin/11)
Similarly, the maximum permissible data frame length can be calculated as follows.
10
× FLmax = 11 × FL −
11
21k − 2
FLmax =
20k
Therefore, the minimum receivable baud rate at the transmission destination is as follows.
BRmin = (FLmax/11)
The permissible baud rate error between UART0 and the transmission destination can be calculated from the
above minimum and maximum baud rate expressions, as follows.
Table 11-5. Maximum/Minimum Permissible Baud Rate Error
Division Ratio (k)
8
16
24
31
Remarks 1. The permissible reception error depends on the number of bits in one frame, input clock
frequency, and division ratio (k). The higher the input clock frequency and the higher the division
ratio (k), the higher the permissible reception error.
2. k: Set value of BRGC0
222
22k
−
1
=
Brate
21k + 2
21k − 2
k + 2
× FL =
FL
2 × k
2 × k
FL × 11
20k
−
1
=
Brate
21k − 2
Maximum Permissible Baud Rate Error
+3.53%
+4.14%
+4.34%
+4.44%
Preliminary User's Manual U16846EJ1V0UD
µ
PD78F0102H AND 78F0103H ONLY)
k − 2
21k + 2
× FL =
FL
2k
2k
Minimum Permissible Baud Rate Error
−3.61%
−4.19%
−4.38%
−4.47%