ADVANCED EQ (FIR)

The ADVANCED EQ currently supports loading FIR impulse responses to be convoluted
over the output signal. (see:
Once a file is loaded, it the FIR filter engine can be ENABLED/DISABLED via the toggle
button. The TAPS indicates the length of the filter, while the CRC value is a simple
checksum over all coefficients, which easily allows the user to compare different
revisions of files. The same CRC on different channels guarantees that exactly the same
FIR filter is loaded.
The FIR engine always runs on 1xFS of the selected input sync interface.
(e.g. 32, 44.1, 48kHz) Thus, the FIR coefficients have to export for the
desired sample rate and can not be dynamically adapted.