It's pretty handy to use the SYNC WITH HOSTNAME option, which will use
the amplifier's HOSTNAME and append -DANTE to it, which is used as
Dante IDENTITY.
6.8.3. TIME
Set system time and time zone. If the device is connected to the internet, it will try to
synchronize its RTC (real time clock) to an NTP time-server. The system time is mainly
used in Syslog entries to tag events.
6.8.4. PSU
Measures the mains voltage, which is used for derating the PSU in 100 / 110V cases. If
the device has more than one PSU, it will indicate which one is plugged in. (HP² only)
When LOAD reaches 100%, the overall power limiter will reduce the output level of all
channels simultaneously, not to overload the PSU. The REDUCTION meter is also shown
on the OVERVIEW page as REDUCT HW level meter.
2023-01-05 | Rev. 3.17.0
MAXX/HP²
Chapter 6. WEBSITE
6.8. DEVICE
6.8. DEVICE | 68/86