6.6.10. DELAY
In the CONFIG column, the current value for all selected channels can be seen. In the
upper half of the pop-up, a dedicated value can be set to all selected channels.
The delay units is either m (meters), ms (milliseconds) or samples. An additional
Ahead Delay
is added separately and is NOT calculated in the overall CONFIG value but
is indicated in the right column.
When setting the delay in m, an air temperature has to be specified to calculate the
speed of sound.
The values for ms and m will be calculated with given temperature and/or
samplingrate. The result will be round to samples.
2023-01-05 | Rev. 3.17.0
MAXX/HP²
Chapter 6. WEBSITE
6.6. CHANNEL SETTINGS
Look
show calced value.
6.6. CHANNEL SETTINGS | 46/86