ADVANCED EQ (FIR)
The ADVANCED EQ currently supports loading FIR impulse responses to be convoluted over the
output signal. (see:
Supported File
Once a file is loaded, it the FIR filter engine can be ENABLED/DISABLED via the toggle button.
The TAPS indicates the length of the filter, while the CRC value is a simple checksum over all
coefficients, which easily allows the user to compare different revisions of files. The same CRC on
different channels guarantees that exactly the same FIR filter is loaded.
The FIR engine always runs on 1xFS of the selected input sync interface. (e.g. 32,
44.1, 48kHz) Thus, the FIR coefficients have to export for the desired sample rate
and can not be dynamically adapted.
2024-02-07 | Rev. 3.20.3.1
Formats)
MAXX/LP² 6.6. CHANNEL SETTINGS | 57/97