Filter/Breather Replacement; Hcu Maintenance Schedule - Schulte GLADIATOR RWP-1935 Operator's Manual

Variable width rock windrower/picker
Table of Contents

Advertisement

Filter/Breather Replacement

1. Before replacing the filter please make sure to shut down the system and allow it to cool down.
2. Unscrew and remove the filter cap from the tank
3. Remove the O-ring seal, filter bypass spring and filter from the unit. Place the filter cap on top of the filter
port without applying any torque to avoid dust/debris entering the system.
4. Withdraw the old filter and replace it with the new filter and place the bypass spring and O-ring seal as
shown and tighten the filter cap. The torque required to tighten the filter cap is around 75 to 85 ft-lbs.
5. Unscrew the breather cap and replace with the new one.
6. The breather cap is made out of plastic and comes with SAE-12 1-1/16-12 thread so the torque required to
tighten the breather cap is 78 ft-lbs. per SAE guidelines.
7. While tightening the filter/breather, it is the responsibility of the operating personnel to not damage the
threads on the ports as it will lead to potential cracks near the openings.
Do not open the internal bypass valve assembly port. Warranty is void if it has been
opened, tampered, or damaged by the customer.

HCU Maintenance Schedule

Every 3 Months
• Check for any leaks in the system
• Inspect the hoses and fittings. Tighten them if they are loose.
• Clean the outer grille and make sure there is no obstacle blocking the airflow to the system.
• Check for potential cracks in the mounting brackets.
• Inspect high pressure hose lines for bends, wear and tear.
Every 9 Months
• All of the 3 month Maintenance items
• Replace filter and breather
Gladiator RWP-1935 01/23
© 2023 Alamo Group Inc.
MAINTENANCE
Maintenance Section 5-10

Advertisement