SECTION 5
SETTINGS & PROGRAMMING
PROGRAMMING ADDITIONAL
SPRAYER SETTINGS

Setting up Spray Job Pre-sets

Enter the CAL (Sprayer setting) screen and press and hold
the pre-set number you want to configure, after 3 seconds
a red square will appear next to the number. Press the red
square and it will take you to another screen where you
can set the rate and row width.
The operator can now select 1, 2 or 3 to lock in a Spray
job which will be transferred onto the Main Spray screen.
NOTE - The Operator will still need to select the
appropriate TIER SELECTION for the chosen Spray Job.
24
HT-OMFUSION-A

Programming the Wind Compensation Function

Press HYD
(Hydraulic setting menu).
Press Master Fan speed
This will set the fan speed that will be "pushing" into an
opposing cross wind. (In most instances this will be set to
the Max. speed, however, it will also be relative to canopy
density and growth stage.
Press Wind Comp Offset.
This will set the fan speed on the "wind assisted" side of
the sprayer. (Set to a speed that ensures maximum spray is
contained in the canopy and doesn't penetrate through as
off target drift.
When setting the Wind Compensation Function, it is
highly recommended to use an observer to determine
and film (using a mobile phone) sprayer
performance & penetration to achieve
optimum sprayer coverage whilst
minimising off target drift.
When satisfied with the Master Fan speed
(MAX.) and Wind Comp Offset (MIN.)
settings return to the Main Spray screen.
***The Operator must ensure that the Left and Right facing
fans are at the correct orientation to the cross wind before
commencing spraying.
The Left and Right fan speed is displayed on the Main
Spray screen along with a Red (Left) and Green (Right)
arrow to simplify orientation.
To change over or invert the Fan speed settings at the end
of the completed row the operator will double click the
left or right lower button on the Fusion Joystick control to
perform the directional fan speed change.
WindComp (see more re WindComp on pages 1 1,
14 & 16).