Hitachi Relion 650 Series Technical Manual page 80

Hide thumbs Also See for Relion 650 Series:
Table of Contents

Advertisement

Section 9
Control
Name
COMPOFCL3
COMPOFOL1
COMPOFOL2
COMPOFOL3
ADAPTCL1
ADAPTCL2
ADAPTCL3
SCATOFL1
SCATOFL2
SCATOFL3
ARCEXTL1
ARCEXTL2
ARCEXTL3
LOCCNTLIN
CMPLOSIN
CBOPCAPIN
LOADTYPE
GROUNDING
EXTSTGY
LD1CLANL1
LD1CLANL2
LD1CLANL3
LD2CLANL1
LD2CLANL2
LD2CLANL3
Table 33:
Name
OPCMDL1
OPCMDL2
OPCMDL3
CLCMDL1
CLCMDL2
CLCMDL3
OPCMDINP
CLCMDINP
EMERTRIP
OPBYPASS
CLBYPASS
BLKOPL1
Table continues on next page
74
Type
Default
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
BOOLEAN
BOOLEAN
INTEGER
INTEGER
INTEGER
BOOLEAN
REAL
REAL
REAL
REAL
REAL
REAL
SSCPOW Output signals
Type
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
BOOLEAN
© 2021 Hitachi Energy. All rights reserved.
Description
0.0
Mechanical compensation offset for closing instant in phase L3
0.0
Mechanical compensation offset for opening instant in phase L1
0.0
Mechanical compensation offset for opening instant in phase L2
0.0
Mechanical compensation offset for opening instant in phase L3
0.0
Adaptive switching correction offset for phase L1
0.0
Adaptive switching correction offset for phase L2
0.0
Adaptive switching correction offset for phase L3
0.0
Switching target offset for mechanical closing time scatter in
phase L1
0.0
Switching target offset for mechanical closing time scatter in
phase L2
0.0
Switching target offset for mechanical closing time scatter in
phase L3
0.0
Adaptive extension of target arcing time for opening of phase L1
0.0
Adaptive extension of target arcing time for opening of phase L2
0.0
Adaptive extension of target arcing time for opening of phase L3
0
Local control indication
0
Loss of compensation input signal
0
Circuit breaker operating capability input from MONALM
1
Type of switched load for selecting opening and closing strategy
0
Type of grounding for selected load type
0
Apply external switching targets
0.0
Load 1 external target making angle in degrees for phase L1
0.0
Load 1 external target making angle in degrees for phase L2
0.0
Load 1 external target making angle in degrees for phase L3
0.0
Load 2 external target making angle in degrees for phase L1
0.0
Load 2 external target making angle in degrees for phase L2
0.0
Load 2 external target making angle in degrees for phase L3
Description
Time activated synchronous open command for phase L1
Time activated synchronous open command for phase L2
Time activated synchronous open command for phase L3
Time activated synchronous close command for phase L1
Time activated synchronous close command for phase L2
Time activated synchronous close command for phase L3
Latched received Open command
Latched received Close command
Emergency trip indication for immediate trip operation
Open command bypasses point-on-wave control
Close command bypasses point-on-wave control
Open operation blocked in phase L1
1MRK 511 557-UEN Rev. A
PID-7616-OUTPUTSIGNALS v2
Technical Manual