7.3 Realtime-Ethernet module
ma_dr_s6-cu-a-inst-20109645_en
Status
Bus off
Invalid configuration
Warning limit reached
Error control event
Sync error
Legend
The real-time Ethernet module is depending on the ordered variant. It includes dif-
ferent fieldbus controls. The active fieldbus control is set with parameter fb68.
The description is given in a separate manual at the following link:

Realtime-Ethernet module

https://www.keb.de/fileadmin/media/Manuals/dr/
ma_dr_rte-inst-20148981_en.pdf
Fieldbus interfaces | 7
Light pattern
r (permanent)
r-0 (grid 200 ms)
r-0-0-0-0-0 (grid 200 ms)
r-0-r-0-0-0-0-0 (grid 200
ms)
r-0-r-0-r-0-r-0-0-0-0-0 (grid
200 ms)
r: Red
g: Green
0: off
Description
CAN bus switched off.
General configuration er-
ror.
An error counter has
reached or exceeded the
warning level.
A Guard or Heartbeat
event has occurred.
SYNC message has not
been received within the
set time-out time.
The red/green signals are
shifted by 180°. In case of
overlapping, red has prior-
ity.
29