Terminal Strip X2A; Digital Inputs; Table 9 Assignment Of The Terminal Strip X2A - KEB COMBIVERT S6 Instructions For Use Manual

Installation control applikation
Hide thumbs Also See for COMBIVERT S6:
Table of Contents

Advertisement

4 | Connection of the control
4.2 Terminal strip X2A
2
1
PIN
Name
Description
1
DI1 / AN3
Digital input 1 / analog input 3 (switchable via software)
2
DI2
Digital input 2
3
DI3
Digital input 3
4
DI4
Digital input 4
5
DI5
Digital input 5
6
DI6
Digital input 6
7
DI7
Digital input 7
8
DI8
Digital input 8
9
0V
Reference potential for digital output
10
DO1
Digital output 1
11
0V
Reference potential for digital output
12
DO2
Digital output 2
13
RLB
Relay output / NC contact
14
RLA
Relay output / NO contact
15
RLC
Relay output/ switching contact
16
24Vout
DC voltage output 24V (max. 100 mA together with terminal 26) for control the inputs (SELV).
17
AN1-
non-isolated difference input 1
18
AN1+
Non-isolated difference input 1
19
AN2-
non-isolated difference input 2
20
AN2+
Non-isolated difference input 2
21
0V
Reference potential for analog inputs and outputs
22
ANOUT
Analog output DC 0...10 V
23
CAN low
CAN bus ISO High Speed according to ISO/DIN 11896 => fieldbus interfaces
24
CAN high
CAN bus ISO High Speed according to ISO/DIN 11896 => fieldbus interfaces
25
CAN GND
CAN ground isolated => fieldbus interfaces
26
24Vout
DC voltage output 24V (max. 100 mA together with terminal 16) for control the inputs (SELV).
27
0V
Reference potential for P24Vin at external supply
28
P24Vin
Voltage output DC 24V for supply the control board
Table 9: Assignment of the terminal strip X2A
4.2.1 Digital Inputs
Specification
18
4
6
8
10
12
3
5
7
9
11
Number
Name
14
16
18
20
22
13
15
17
19
21
8
DI1...DI8
KEB Automation KG
24
26
28
23
25
27
ma_dr_s6-cu-a-inst-20109645_en