The following response is observed when an attempt is made to SWLD a
non-RLCM-EDC unit.
>SWLD UNIT 0
Example of MAP response
LCM HOST 05 0 Unit 0: Request Invalid
The following response is observed when an attempt is made to SWLD an
RLCM-EDC unit and the system is unable to check the loadnames from the
LCM unit
Example of MAP response
>SWLD UNIT 0
WARNING: Could not retrieve the loadnames.
The following table, "Options of the SWLD command," lists parameters and
options for the SWLD command.
Options of the SWLD command
Parameter
Value
DEVICE
UNIT, PM
NOWAIT
NOWAIT
ALL
ALL
LCM MEMSIZE must be 4M in table LCMINV
Description
The SWLD command is used on a unit or whole PM as
determined by the device option.
When the SWLD command is used with the option
NOWAIT, a prompt is returned to operating company
personnel while continuing to execute the command.
This option allows operating company personnel to
execute the SWLD command on a set of posted
RLCM-EDCs.