Nortel DMS-100 Series Maintenance Manual page 289

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP display
9
To query the out-of-service (OOS) LCM unit for valid loadfiles, type
>QUERYPM OOS
and press the Enter key.
Example of a MAP response
PM Type: LCM
Int. No.: 9
LCM REM1 02 0
ESA equipped: No, Intraswitching is Off
Loadname: LCMINV – REDC07AA
Unit0 Loads: Act– REDC07AB Stby– REDC07AA
Unit1 Loads: Act– REDC07AB
REX is ON; INCOMPLETE on SAT. 1995/10/28 at 01:35:19
Node Status: {OK, FALSE}
Unit 0 Status: {OK, FALSE}
Unit 1 Status: {MAN_BUSY, FALSE}
Site Flr RPos
REM1
01
K03
Services : NEUTRAL
If loadfile names
are valid
are invalid or corrupted
10
To return the LCM unit to service, type
>RTS UNIT lcm_unit
and press the Enter key.
where
lcm_unit
is the LCM (0 or 1) busied in step 4
If RTS
passes
fails
RLCM-EDC card replacement procedures 6-101
Status index: 7
Memory Size – Unit 0: 4M , Unit 1: 4M
*FLT* Stby– REDC07AA
Bay_id
Shf
Description
RLCM 02
04
LCM
Do
step 13
step 11
DMS-100 Family Maintenance Manual ABSK007
NT6X53 card
in LCM
Node_No: 40
Slot
02 0
Do
step 10
step 11
(continued)
*FLT*
EqPEC
6X04AA