5-4 RLCM-EDC alarm clearing procedures
PM LCM
critical
(continued)
Summary of clearing a PM LCM critical alarm (continued)
RTS
2
passed?
N
CBsy
fault?
N
Load
failure?
N
Card list?
Contact
maintenance
support group
297-8381-550 Standard 02.02 April 1999
Y
End of
procedure
Y
3
Y
Query LCM for
valid loadfiles
Y
Are loadfiles
4
N
Load LCM
Contact
maintenance
support group
Y
valid?
N
Y
Load
RTS the LCM
passed?
unit with the
SWLD option
N
RTS SWLD
Contact
maintenance
support group
Y
passed?
N
End of
procedure