Nortel DMS-100 Series Maintenance Manual page 268

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-80 RLCM-EDC card replacement procedures
NT6X50
in HIE
(continued)
How to replace an NT6X50 card in an HIE
At your current location
1
2
At the MAP display
3
4
5
297-8381-550 Standard 02.02 April 1999
Obtain a replacement card. Make sure that the replacement card has the same
product equipment code (PEC) and suffix as the card to remove.
If another maintenance procedure directed you to this procedure, proceed to
step 4. If this event did not occur, proceed to step 3.
To access the peripheral module (PM) level and post the line concentrating
module (LCM), type
>MAPCI;MTC;PM;POST LCM site cabinet lcm
and press the Enter key.
where
site
is the name of the RLCM-EDC site (alphanumeric)
cabinet
is the number of the RLCC cabinet
lcm
is the number of the LCM
To display C-side link information, type
> TRNSL C
and press the Enter key.
Example of a MAP response:
Link 0: LTC 0
Link 1: LTC 0
From the display in step 4, determine the C-side PM to which the RLCM-EDC
connects. To post the C-side PM, type
> POST LTC ltc_no
and press the Enter key.
where
ltc_no
is the number of the host LTC+ (0 to 255)
LTC P-side link numbers
2; Cap MS; Status: OK
6; Cap MS; Status: SysB
;MsgCond: OPN
;MsgCond: CLS

Advertisement

Table of Contents
loading

Table of Contents