Nortel DMS-100 Series Maintenance Manual page 278

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-90 RLCM-EDC card replacement procedures
NT6X51
NT6X51
in LCM
in LCM
(continued)
(end)
9
10
11
12
13
14
297-8381-550 Standard 02.02 April 1999
To load the LCM unit, type
>LOADPM UNIT unit_no CC
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) to load
If the load
passed
failed
To return the LCM unit to service and switch load to the standby bank, type
>RTS UNIT lcm_unit SWLD
and press the Enter key.
where
lcm_unit
is the LCM unit (0 or 1) busied in step 4
If RTS
passed
failed
Send any defective cards for repair according to local procedure.
Record the items that follow in office records:
date that card replacement occurred
serial number of the card
indications that prompted replacement of the card
Proceed to step 14.
For additional help in this card replacement, contact the next level of support.
This procedure is complete.
Do
step 10
step 13
Do
step 11
step 13